Product no longer stocked – limited availability
Contact for pricing and lead time--a minimum order quantity may apply
Product no longer stocked – limited availability
Contact for pricing and lead time--a minimum order quantity may apply
Product no longer stocked – limited availability
Contact for pricing and lead time--a minimum order quantity may apply
Product no longer stocked – limited availability
Contact for pricing and lead time--a minimum order quantity may apply

The SG-Link® -LXRS® is a small, low-power, two-channel analog input sensor node with many sampling options.

Product Highlights

  • One differential and one single-ended analog input channel and an internal temperature sensor
  • Ideal for remote and long term measurement of many Wheatstone bridge and analog-type sensors including: strain, force, torque, pressure, acceleration, vibration, magnetic field, displacement and geophones
  • Supports continuous, burst, and event-triggered sampling and datalogging to internal memory
  • User-programmable sample rates up to 4096 Hz
  • IP65/66 environmental enclosures available
Datasheet Manual Software

The TC-Link® -6CH -LXRS® is a specialized node designed for synchronous, lossless data acquisition from up to six standard thermocouples.

Product Highlights

  • Six standard mini thermocouple inputs, an embedded cold junction temperature compensation sensor, and optional integrated relative humidity sensor
  • On-board linearization algorithms are software programmable to support a wide range of thermocouple types, including J, K, N, R, S, T, E, and B
  • High resolution data with 24-bit A/D converter
  • Simultaneously transmit real-time data and log to memory.
  • IP65/66 environmental enclosures available
Datasheet Software

The SG-Link®-OEM-LXRS® is a small, wireless, low-cost, extended range, two-channel analog input sensor node ready for OEM integration.  

Product Highlights

  • One differential and one single-ended analog input channel and an internal temperature sensor
  • Ideal for remote and long term measurement of many Wheatstone bridge and analog-type sensors including: strain, force, torque, pressure, acceleration, vibration, magnetic field, displacement and geophones
  • Supports continuous, burst, and event-triggered sampling and datalogging to internal memory
  • User-programmable sample rates up to 4096 Hz
  • Comprehensive SDK and OEM form factor for rapid integration
  • Simultaneously transmit real-time data and log to memory
Datasheet Software

The SG-Link® -RGD -LXRS® ia a versatile, ruggedized four-channel analog sensor node with integrated triaxial accelerometer.

Product Highlights

  • Four analog input channels, integrated three-axis accelerometer, and an internal temperature sensor
  • Integrated strain sensor signal conditioning, embedded processing, and environmentally hardened form factor ideal for permanently mounting over strain gauges
  • Supports conventional bonded foil, piezoelectric-resistive, Wheatstone bridge, and modular Columbia Research
  • Labs-type strain gauges
  • Integrated triaxial accelerometer with MEMS technology and +/- 16 g range
  • User-programmable sample rates up to 4096 Hz
Datasheet Software

Wireless Simplicity, Hardwired Reliability

High Performance

  • Scalable, long range wireless sensor networks up to 2 km
  • Lossless data throughput under most operating conditions

Ease of Use

  • Rapid deployment with wireless framework
  • Low power consumption allows extended use.
  • Remotely configure nodes, acquire and view sensor data with Node Commander®.
  • Optional web-based SensorCloud™ interface optimizes data storage, viewing, and analysis.
  • Easy integration via comprehensive SDK

Cost Effective

  • Out-of-the box wireless sensing solution reduces development and deployment time.
  • Volume discounts

Wireless Simplicity, Hardwired Reliability

High Performance

  • Node-to-node synchronization up to ±32 microseconds
  • Support for hundreds of simultaneous sampling wireless sensor nodes
  • Lossless data throughput under most operating conditions
  • Extended wireless communication range to 2km

Ease of Use

  • Rapid deployment with wireless framework
  • Standard miniature thermocouple blade connectors
  • Remotely configure nodes, acquire and view sensor data with Node Commander®.
  • Easy integration via comprehensive SDK

Cost Effective

  • Reduction of costs associated with wiring
  • Low-cost per channel with six thermocouples per node
  • Volume discounts

Wireless Simplicity, Hardwired Reliability

High Performance

  • Scalable, long range wireless sensor networks up to 2 km
  • Lossless data throughput under most operating conditions

Ease of Use

  • Rapid deployment with wireless framework
  • Low power consumption allows extended use.
  • Wide range of sample rates and duty cycles
  • Optional web-based SensorCloud™ interface optimizes data storage, viewing, and analysis.

Cost Effective

  • Out-of-the box wireless sensing solution reduces development and deployment time.
  • Volume discounts

Wireless Simplicity, Hardwired Reliability

High Performance

  • Node-to-node synchronization up to ±32 microseconds
  • High resolution data with 16-bit A/D converter
  • Scalable, long range wireless sensor networks up to 2 km

Ease of Use

  • Flex bonding cable and node form factor allow quick installation over existing strain gauges
  • Low profile, environmentally sealed enclosure
  • On-board shunt calibration

Cost Effective

  • Reduction of costs associated with wiring
  • Out-of-the box wireless sensing solution reduces development and deployment time.

General

Sensor input channels

Differential analog, 1 channel

Single-ended analog, 1 channel

Integrated sensors

Internal temperature, 1 channel

Data storage capacity

2 M bytes (up to 1,000,000 data points, data type dependent)

Analog Input Channels

Measurement range

Differential: full-bridge, 350 Ω (factory configurable) Single-ended: 0 to 3 V dc

Accuracy

± 0.1% full scale typical

Resolution

12 bit

Anti-aliasing filter bandwidth

Single-pole Butterworth

-3 dB cutoff @ 250 Hz (factory configurable)

Bridge excitation voltage

+3 V dc, 50 mA total for all channels

(pulsed @ sample rates 16 Hz to conserve power)

Measurement gain and offset

User-selectable in software on differential channels gain values from 104 to 1800

Integrated Temperature Channel

Measurement range

-40 °C to 85 °C

Accuracy

± 2 °C (at 25 °C) typical

Resolution

12 bit

Sampling

Sampling modes

Synchronized, low duty cycle, datalogging

Sampling rates

Continuous sampling: 1 sample/hour to 512 Hz

Periodic burst sampling: 32 Hz to 4096 Hz

Datalogging: 32 Hz to 4096 Hz

Sample rate stability

± 3 ppm

Network capacity

Up to 2000 nodes per RF channel (and per gateway) depending on the number of active channels and sampling settings. Refer to the system bandwidth calculator: http://www.microstrain.com/configure-your-system

Synchronization between nodes

± 32 μsec

Operating Parameters

Radio frequency (RF)

transceiver carrier

2.405 to 2.470 GHz direct sequence spread spectrum over 14 channels, license free worldwide, radiated power programmable from 0 dBm (1 mW) to 16 dBm (39 mW); low power option available for use outside the U.S.- limited to 10dBm (10mW)

Range for bi-directional RF link

70 m to 2 km line of sight with RF power setting

RF communication protocol

IEEE 802.15.4

Power source

Internal: 3.7 V dc, 250 mAh lithium ion rechargeable battery

External: +3.2 to +9.0 V dc

Power consumption

See power profile :

http://files.microstrain.com/SG-Link-LXRS-Power-Profile.pdf

Operating temperature

-20 ˚C to + 60 ˚C (extended temperature range available with custom battery/enclosure, -40 ˚C to + 85 ˚C electronics only)

Acceleration limit

500 g standard (high g option available)

Physical Specifications

Dimensions

58 mm x 50 mm x 21 mm

Weight

42 grams

Environmental rating

Indoor use (IP65/66 enclosures available)

Enclosure material

ABS plastic

Integration

Compatible gateways

All WSDA® base stations and gateways

Compatible sensors

Bridge type analog sensors, 0 to 3 V dc analog sensors

Connectors

Screw terminal block

Shunt calibration

Internal shunt calibration resistor 499 KΩ, differential channel

Software

SensorCloud™, SensorConnect™, Node Commander®, Windows 7 (or newer)

Software development

Open-source MicroStrain Communications Library (MSCL) with sample code available in C++,Python,and.NET formats (OS and computing platform independent): http://lord-microstrain.github.io/MSCL/

Regulatory compliance

FCC (U.S.), IC (Canada), ROHS

General

Sensor input channels

Thermocouple input, 6 channels

Integrated sensors

Temperature CJC, 1 channel

Relative humidity (optional), 1 channel

Data storage capacity

2 Megabytes (up to 500,000 data points)

Thermocouple Input

Measurement range

-210 °C to 1820 °C (depending on the thermocouple type)

Accuracy

± 0.1 % of full scale or ± 2 °C, whichever is greater

(does not include error from sensor or wire)

Resolution

0.0625 °C, 24 bit

Repeatability

± 0.1 °C (does not include error from sensor or wire)

Integrated Temperature Cold Junction Compensation (CJC) Channel

Compensation range

-40 °C to 85 °C

Accuracy and resolution

± 0.5 °C (from 0 to 70 °C), 12 bit resolution

Integrated Relative Humidity Channel (optional)

Measurement range

0 to 100 %

Accuracy

± 2 % (10 to 90 % RH), ± 4 % ( 0 to 10% RH and 90 to 100% RH)

Repeatability

± 0.1 %

Sampling

Sampling modes

Synchronized, low duty cycle, datalogging

Sampling rates

Continuous sampling: 1 sample/hour to 8 Hz

Datalogging: 1 sample/hour to 8 Hz

Sample rate stability

± 3 ppm

Network capacity

Up to 2000 nodes per RF channel (and per gateway) depending on the number of active channels and sampling settings. Refer to the system bandwidth calculator: http://www.microstrain.com/configure-your-system

Synchronization between nodes

± 32 μsec

Operating Parameters

Radio frequency (RF)

transceiver carrier

2.405 to 2.470 GHz direct sequence spread spectrum over 14 channels, license free worldwide, radiated power programmable from 0 dBm (1 mW) to 16 dBm (39 mW); low power option available for use outside the U.S.- limited to 10dBm (10mW)

Range for bi-directional RF link

70 m to 2 km line of sight with RF power setting

RF communication protocol

IEEE 802.15.4

Power source

Embedded internal: 3.7 V dc, 650 mAh rechargeable Li-poly battery

Replaceable internal (not included): 3.6 V dc type AA Lithium-thionyl chloride (LiSOCI2)

External: 3.2 V dc to 9 V dc

Power consumption

See power profile : http://files.microstrain.com/TC-Link-6CH- LXRS-Power-Profile-1.pdf

Operating temperature

-20 ˚C to + 60 ˚C (extended temperature range available with custom battery/enclosure, -40 ˚C to + 85 ˚C electronics only)

Acceleration limit

500 g standard (high g option available)

MTBF 1,500,000 hours (Telcordia method, SR332)

Physical Specifications

Dimensions

129 mm x 73 mm x 28 mm excluding switch

Weight

151 grams

Enclosure material

ABS plastic

Environmental rating

Indoor use (IP65/66 enclosures available)

Integration

Compatible gateways

All WSDA® base stations and gateways

Compatible sensors

Type J, K, N, R, S, T, E and B thermocouples

Connectors

Type-1 standard mini (SM) connectors for flat pin thermocouples

Software

SensorCloud™, SensorConnect™, Node Commander®, Windows 7 (or newer)

Software development

Open-source MicroStrain Communications Library (MSCL) with sample code available in C++,Python,and.NET formats (OS and computing platform independent): http://lord-microstrain.github.io/MSCL/

Regulatory compliance

FCC (U.S.), IC (Canada), ROHS

 

General

Sensor input channels

Differential analog, 1 channel

Single-ended analog, 1 channel

Integrated sensors

Internal temperature, 1 channel

Data storage capacity

2 M bytes (up to 1,000,000 data points, data type dependent)

Analog Input Channels

Measurement range

Differential: full-bridge, 350 Ω (factory configurable) Single-ended: 0 to 3 V dc

Accuracy

± 0.1% full scale typical

Resolution

12 bit

Anti-aliasing filter bandwidth

Single-pole Butterworth

-3 dB cutoff @ 250 Hz (factory configurable)

Bridge excitation voltage

+3 V dc, 50 mA total for all channels

(pulsed @ sample rates 16 Hz to conserve power)

Measurement gain and offset

User-selectable in software on differential channels gain values from 104 to 2560

Integrated Temperature Channel

Measurement range

-40 °C to 85 °C

Accuracy

± 2 °C (at 25 °C) typical

Resolution

12 bit

Sampling

Sampling modes

Synchronized, low duty cycle, datalogging

Sampling rates

Continuous sampling: 1 sample/hour to 512 Hz

Periodic burst sampling: 32 Hz to 4096 Hz

Datalogging: 32 Hz to 4096 Hz

Sample rate stability

± 3 ppm

Network capacity

Up to 2000 nodes per RF channel (and per gateway) depending on the number of active channels and sampling settings. Refer to the system bandwidth calculator: http://www.microstrain.com/configure-your-system

Synchronization between nodes

± 32 μsec

Operating Parameters

Radio frequency (RF)

transceiver carrier

2.405 to 2.470 GHz direct sequence spread spectrum over 14 channels, license free worldwide, radiated power programmable from 0 dBm (1 mW) to 16 dBm (39 mW); low power option available for use outside the U.S.- limited to 10dBm (10mW)

Range for bi-directional RF link

70 m to 2 km line of sight with RF power setting

RF communication protocol

IEEE 802.15.4

Power source

External: +3.2 to +9.0 V dc (9 V dc alkaline battery provided)

Power consumption

See power profile : http://files.microstrain.com/SG-Link-OEM- LXRS-Power-Profile.pdf

Operating temperature

-40 ˚C to + 85 ˚C (excluding 9 V battery)

Acceleration limit

500 g standard (high g option available)

MTBF 1,300,000 hours (Telcordia method, SR332)

Physical Specifications

Dimensions

56 mm x 20 mm x 6 mm

Weight

7 grams

Integration

Compatible gateways

All WSDA® base stations and gateways

Compatible sensors

Bridge type analog sensors, 0 to 3 V dc analog sensors

Connectors

Solder pads or screw terminal connector

Shunt calibration

Internal shunt calibration resistor 499 KΩ, differential channel

Software

SensorCloud™, SensorConnect™, Node Commander®, Windows 7 (or newer)

Software development

Open-source MicroStrain Communications Library (MSCL) with sample code available in C++,Python,and.NET formats (OS and computing platform independent): http://lord-microstrain.github.io/MSCL/

Regulatory compliance

FCC (U.S.), IC (Canada), ROHS

 

General

Sensor input channels

Differential analog, 4 channels

Integrated sensors

Triaxial MEMS accelerometer, 3 channels

Internal temperature, 1 channel

Data storage capacity

2 M bytes (up to 1,000,000 data points, data type dependent)

Analog Input Channels

Measurement range

Differential: full-bridge, 350 Ω (factory configurable)

Accuracy and resolution

± 0.1% full scale typical, 16 bit resolution

Anti-aliasing filter bandwidth

Single-pole Butterworth

-3 dB cutoff @ 250 Hz

Bridge excitation voltage

+2.7 V dc, 50 mA total for all channels

(pulsed @ sample rates 16 Hz to conserve power)

Measurement gain and offset

User-selectable in software on differential channels gain values from 104 to 1800

Integrated Accelerometer Channels

Measurement range

± 16 g

Accuracy and resolution

± 4 mg, 13 bit resolution

Integrated Temperature Channel

Measurement range

-40 °C to 85 °C

Accuracy and resolution

± 2 °C (at 25 °C) typical, 16 bit resolution

Sampling

Sampling modes

Synchronized, low duty cycle, datalogging

Sampling rates

Continuous sampling: 1 sample/hour to 512 Hz

Periodic burst sampling: 32 Hz to 4096 Hz

Datalogging: 32 Hz to 4096 Hz

Sample rate stability

± 3 ppm

Network capacity

Up to 2000 nodes per RF channel (and per gateway) depending on the number of active channels and sampling settings. Refer to the system bandwidth calculator: http://www.microstrain.com/configure-your-system

Synchronization between nodes

± 32 μsec

Operating Parameters

Radio frequency (RF)

transceiver carrier

2.405 to 2.470 GHz direct sequence spread spectrum over 14 channels, license free worldwide, radiated power programmable from 0 dBm (1 mW) to 16 dBm (39 mW); low power option available for use outside the U.S.- limited to 10dBm (10mW)

Range for bi-directional RF link

70 m to 2 km line of sight with RF power setting

RF communication protocol

IEEE 802.15.4

Power source

Replaceable 3.7 V dc, 1.7 Ah Tadiran TL-5935 1/6 D-cell battery

Power consumption

960 uA ( 3.46 mW) @ 3.6 V dc, 32 HZ, 3 ch, no duty cycling

10.6 mA (38.16 mW) @ 3.6 V dc, 256 Hz, 3 ch, no duty cycling

4.0 mA (14.4 mW) @ 3.6 V dc, 256 Hz, 1 ch, no duty cycling

Operating temperature

-40 ˚C to + 85 ˚C

Acceleration limit

500 g standard (high g option available)

Physical Specifications

Dimensions

101 mm x 46 mm x 26 mm

Weight

150 g (including battery)

EMI/EMC rating

MIL-STD-461F

Enclosure material

Clear polycarbonate

Integration

Compatible gateways

All WSDA® base stations and gateways

Compatible sensors>

Bridge type analog sensors

Connectors

Flex cable terminal/solder pads (flex cable included)

Shunt calibration

Internal shunt calibration resistor 499 KΩ, differential channels<

Software<

SensorCloud™, SensorConnect™, Node Commander®, Windows 7 (or newer)

Software development

Open-source MicroStrain Communications Library (MSCL) with sample code available in C++,Python,and.NET formats (OS and computing platform independent): http://lord-microstrain.github.io/MSCL/

Regulatory compliance

FCC (U.S.), IC (Canada), ROHS

 

General Documentation

Technical Notes

Mechanical Drawings (uncontrolled)

Videos