Use the filters below to search for vibration measurement solutions in our Wireless Sensor Systems.

1. SELECT A VIBRATION NODE
Select nodes with integrated sensors for an all-in-one solution, or choose nodes with sensor inputs to convert LORD MicroStrain and third-party wired sensors into dispersed wireless networks.

Measurement Range

Number of Channels

Sampling Rate

Operating Environment

All taxonomy terms Sampling Resolution
3661, 2761, 3666, 3671, 3676, 3681, 2711, 1436, 3686, 3801, 3836, 1771, 2736, 3736, 3831, 2781, 1486, 3691, 1451, 39, 1441, 3696, 1726, 501, 1766, 1456, 3701, 1461, 1466, 1471, 43, 1476, 1481, 23, 556

IEPE-Link™ -LXRS®

Add to System
1 IEPE transducer input
Sampling Continuous:
N/A

Periodic Burst:
1 kHz to 104 kHz

Datalogging:
N/A

24 - bit
3661, 3666, 3671, 3681, 2711, 2716, 3731, 3826, 1436, 3686, 3631, 3641, 1771, 2731, 1486, 1756, 3691, 1451, 1721, 1776, 3456, 1761, 1491, 39, 1441, 3696, 501, 1461, 1466, 47, 1471, 1476, 23, 556

G-Link2™ -LXRS®

Add to System
3-axis accelerometer (option 1)
1-axis accelerometer (option 2)
Sampling Continuous:
32 Hz to 512 Hz

Periodic Burst:
32 Hz to 10 kHz

Datalogging:
32 Hz to 10 kHz

16 - bit
3661, 3671, 3726, 3821, 2711, 2716, 1436, 3631, 3641, 3636, 3646, 1771, 1716, 2726, 1486, 1756, 1776, 3456, 1491, 39, 1441, 501, 42, 23, 556

G-Link® -LXRS®

Add to System
3-axis accelerometer
Sampling Continuous:
1 sample/hr to 512 Hz

Periodic Burst:
32 Hz to 4096 Hz

Datalogging:
32 Hz to 4096 Hz

12 - bit
3661, 2761, 3666, 3671, 3676, 2871, 2766, 3681, 2771, 2711, 2811, 2911, 2926, 2086, 3021, 3031, 3421, 2716, 2816, 2931, 3731, 3826, 1436, 3686, 2906, 3631, 3641, 2041, 3636, 3646, 3801, 3836, 1771, 2731, 2831, 2961, 2971, 3311, 2116, 2291, 2626, 2251, 2781, 2891, 3041, 3046, 2091, 3426, 2281, 3096, 3101, 721, 1486, 1836, 2121, 2256, 2646, 821, 2271, 2681, 2916, 3106, 2881, 3081, 38, 3441, 3746, 3761, 3776, 3791, 3811, 3856, 3871, 3881, 3691, 1451, 1721, 2146, 2316, 2666, 1776, 2296, 3076, 2696, 1761, 2641, 2286, 726, 1491, 1841, 2126, 2261, 2651, 3156, 3166, 3196, 3411, 3431, 39, 1441, 3696, 2076, 1781, 501, 1766, 2186, 2631, 831, 3161, 3171, 3066, 37, 1456, 3701, 1786, 3061, 2636, 36, 1461, 1466, 1471, 33, 1476, 27, 1481, 26, 25, 29, 46, 23, 511, 516, 521, 536, 556, 546, 551, 541

V-Link® -LXRS®

Add to System
4 differential analog inputs
3 single-ended analog inputs
Sampling Continuous:
1/hour to 512 Hz

Periodic Burst:
32 Hz to 10 kHz

Datalogging:
32 Hz to 10 kHz

16 - bit
3661, 2761, 3666, 3671, 3676, 2871, 3726, 3821, 3681, 2711, 2811, 2911, 2926, 2086, 3021, 3031, 3421, 2716, 2816, 2931, 3721, 3741, 3756, 3771, 3786, 3806, 3841, 3866, 1436, 3686, 2906, 3631, 3641, 2041, 3636, 3646, 3801, 3836, 1771, 1716, 2066, 2141, 2311, 2661, 2726, 2826, 2956, 2966, 3306, 2116, 2291, 2626, 2251, 2781, 2891, 3041, 3046, 2281, 3096, 3101, 721, 1486, 1836, 2121, 2256, 2646, 821, 2271, 2681, 2916, 3106, 2506, 3081, 38, 3691, 1451, 2296, 3076, 2696, 1761, 1806, 2641, 2286, 726, 1491, 1841, 2126, 2261, 2651, 39, 1441, 3696, 501, 1766, 1656, 2186, 2631, 3066, 37, 1456, 3701, 1786, 3061, 2636, 36, 1461, 1466, 1471, 33, 1476, 27, 1481, 26, 45, 25, 29, 23, 511, 516, 521, 536, 556, 546, 551, 541

SG-Link® -LXRS®

Add to System
1 differential analog input
1 single-ended analog input
Sampling Continuous:
1/hour to 512 Hz

Periodic Burst:
32 Hz to 4096 Hz

Datalogging:
32 Hz to 4096 Hz

12 - bit
3661, 2761, 3666, 3671, 3676, 2871, 3726, 3821, 3681, 2711, 2811, 2911, 2926, 2086, 3021, 3031, 3421, 3721, 3741, 3756, 3771, 3786, 3806, 3841, 3866, 1436, 3686, 2906, 3631, 3641, 2041, 3636, 3646, 3801, 3836, 1771, 1716, 2066, 2141, 2311, 2661, 2726, 2826, 2956, 2966, 3306, 2291, 2626, 2251, 2781, 2891, 3041, 3046, 2281, 721, 1486, 1836, 2121, 2256, 2646, 2721, 2821, 2936, 821, 2271, 2681, 38, 3691, 1451, 2296, 2696, 1761, 1806, 2641, 2286, 2921, 39, 1441, 3696, 501, 1766, 1656, 2186, 2631, 1831, 1846, 1861, 2131, 2266, 2656, 37, 1456, 3701, 1786, 2636, 36, 1461, 1466, 1471, 33, 1476, 27, 1481, 26, 25, 49, 29, 23, 511, 516, 521, 536, 556, 546, 551, 541

SG-Link® -OEM -LXRS®

Add to System
1 differential analog input
1 single-ended analog input
Sampling Continuous:
1/hour to 512 Hz

Periodic Burst:
32 Hz to 4096 Hz

Datalogging:
32 Hz to 4096 Hz

12 - bit
2. SELECT A GATEWAY
Choose one WSDA wireless gateways for each network of sensor nodes.
All taxonomy terms Communications Interface SensorCloud Connectivity Data Storage Memory
80, 81, 58

WSDA® -1500 -LXRS®

Add to System
IEEE 802.3 Ethernet 10/100 Mbps
J1939 CAN (output only)
IEEE 802.15.4 wireless
external cell modem (optional)
Yes
Micro SD 4 GB
79, 57

WSDA® -Base -104 -LXRS®

Add to System
USB 2.0
IEEE 802.15.4 wireless
Upload Only
N/A
79, 3436, 55

WSDA® -Base -101 -LXRS®

Add to System
USB 2.0
analog output
IEEE 802.15.4 wireless
Upload Only
N/A
82, 56

WSDA® -Base -102 -LXRS®

Add to System
RS-232 @ 115,200 (except sync, sampling) and 921,600 bps
IEEE 802.15.4 wireless
Upload Only
N/A