Which product line would you like to select from?

Displacement Sensing Systems

Wireless Sensing Systems

1. SELECT A DISPLACEMENT SENSOR
Choose from our specialty line of the world’s smallest, high-accuracy displacement sensors.

Measurement Range

Actuator Type

Actuator Action

All taxonomy terms Accuracy Range / Resolution / Dimensions
3331, 93, 72, 3611, 3346, 1916, 3051, 1926, 1981, 1936, 1991, 1996, 1946, 25, 3286

M-DVRT®

Add to System

±0.1 % fso (polynomial fit)

±1.5 % fso (linear fit)

1.5 mm 300 nm 11.3 mm x 1.8 mm (dia.)
3 mm 1.5 um 11.3 mm x 1.8 mm (dia.)
6 mm 3 um 18.7 mm x 1.8 mm (dia.)
9 mm 4.5 um 26.8 mm x 1.8 mm (dia.)

 

3331, 93, 3611, 3351, 1916, 3051, 73, 1926, 1981, 1936, 1991, 1996, 1946, 25, 3286

MG- DVRT®

Add to System

±0.1 % (polynomial fit)

±1.0 % (linear fit)

1.5 mm 300 nm 24 mm x 1.8 mm (dia.)
3 mm 1.5 um 24 mm x 1.8 mm (dia.)
6 mm 3 um 40 mm x 1.8 mm (dia.)
9 mm 4.5 um 50 mm x 1.8 mm (dia.)

 

1961, 1906, 3331, 93, 3611, 3346, 1966, 1971, 74, 1976, 1931, 1986, 1936, 1941, 1951, 2001, 25, 2006, 1956, 3286

S- DVRT®

Add to System

±0.1 % (polynomial fit)

±1.0 % (linear fit)

500 um < 125 nm 34.5 mm x 4.76 mm (dia.)
4 mm 1 um 18.5 mm x 4.76 mm (dia.)
6 mm 0.6 um 34.5 mm x 4.76 mm (dia.)
8 mm 2 um 34.5 mm x 4.76 mm (dia.)
24 mm 6 um 81 mm x 4.76 mm (dia.)
38 mm 9.5 um 110 nm x 4.76 mm (dia.)

 

1961, 1906, 3331, 93, 3611, 3351, 1966, 71, 1971, 1976, 1931, 1986, 1936, 1941, 1951, 2001, 25, 2006, 1956, 3286

SG- DVRT®

Add to System

±0.1 % (polynomial fit)

±1.0 % (linear fit)

500 um < 125 nm 50.5 mm x 6 mm (dia.)
4 mm 1 um 30.5 mm x 6 mm (dia.)
6 mm 0.6 um 50.5 mm x 6 mm (dia.)
8 mm 2 um 50.5 mm x 6 mm (dia.)
24 mm 6 um 127 mm x 6 mm (dia.)
38 mm 9.5 um 183 nm x 8 mm (dia.)

 

3611, 481, 3336, 94, 1911, 1921, 25, 3286

NC- DVRT®

Add to System

±0.2 to ±1.0 % (polynomial fit)

1 mm depends on displacement area

4.83 mm x 19.0 mm (10-32 UNF 2A)

2.5 mm depends on displacement area

12.7 mm x 19.0 mm (1/2-20 UNF 2A)

 

2. SELECT A SIGNAL CONDITIONER
Choose an analog or wireless signal conditioner for each sensor.
All taxonomy terms Data Output Recommended Use
1851, 3571, 496, 95, 25, 3286

DEMOD-DVRT®

Add to System

Analog

3421, 3741, 3306, 54, 1836, 95, 3561, 96, 3576, 25, 3286

DVRT-Link™ -LXRS®

Add to System

Wireless to PC (digital)

  • RS232
  • USB (with optional analog outpus)
  • Ethernet/CAN
3571, 95, 3561, 76, 25, 3286

DEMOD-DC®

Add to System

Analog

3571, 95, 3561, 77, 25, 3286

DEMOD- DVRT® -TC

Add to System

Analog