Static accuracy

±0.5° pitch, roll, heading typical for static test conditions

Dynamic accuracy

±2.0° pitch, roll, heading for dynamic (cyclic) test conditions and for arbitrary angles

Important note: Unlike the -25, the -15 does not contain magnetometers.  Magnetometers measure Earth's magnetic fields and provide the AHRS with a reference to produce an accurate heading.  In the -15, the heading is accurate from moment to moment but drifts over time and should not be relied upon.